Distribution

Data Center Transformers

Low-loss, reliable supply for IT, UPS and cooling loads that never switch off.

up to 3,150 kVA · up to 33 kV

Trafo Power oil-immersed transformer with fully enclosed cable box, as used for data center supply

Data sheet

Technical data

Technical data for Data Center Transformers
Ratingup to 3,150 kVA
Voltage classup to 33 kV
Rating
Capacityup to 3,150 kVA
Primary voltage11 / 22 / 33 kV
Secondary voltage415 / 433 V or as specified
Construction
CoreCRGO or amorphous
Insulating liquidMineral oil or synthetic ester
Cooling
CoolingONAN / ONAF
Load
Harmonic dutyDesigned for the specified UPS / IT harmonic spectrum
Standards
Designed toIEC 60076, IS 1180 / IS 2026

Final ratings, losses, impedance and dimensions are confirmed in the guaranteed technical particulars (GTP) for each order.

Overview

Oil-immersed distribution-class transformers for data centers and other mission-critical sites, designed around 24/7 loading, non-linear UPS and IT loads, and redundant supply schemes.

Data centers run their transformers around the clock, so losses, temperature rise and reliability matter more than first cost. Trafo Power designs each unit for the site's load profile: low no-load and load losses for continuous operation, windings sized for the harmonic currents of UPS systems and IT power supplies, and fittings for remote monitoring by the building management system. Units can be supplied for N+1 or 2N redundant configurations and, for indoor or rooftop installation, with synthetic ester fluid for higher fire safety.

Applications

  • Hyperscale and colocation data centers
  • Enterprise and edge data centers
  • Telecom and cloud facilities
  • Mission-critical buildings with UPS-backed supply

Design & engineering features

  • Low no-load and load losses for 24/7 operation
  • Designed for non-linear UPS and IT loads (harmonic / K-factor rating on request)
  • Electrostatic shield between windings on request
  • Low-noise design for indoor and urban sites
  • Mineral oil or synthetic ester (higher fire point) fill
  • Winding and oil temperature monitoring with remote alarms (BMS / SCADA)
  • Hermetically sealed or conservator type

Enquire

Request a quotation for data center transformers

Share what you know — rating, voltages, standards, site and timeline. Our engineers will follow up with a GTP and guaranteed losses.

Technical requirements (as known)

kVA or MVA

Up to 3 files · PDF, DOCX, XLSX, PNG or JPG · 10 MB each