Planned maintenance
Planned maintenance. Fewer outages.
Annual maintenance contracts (AMC) and on-call service for power and distribution transformers, from inspection to emergency repair.

Inspections
Visual checks for leaks and rust; oil moisture, dielectric strength and dissolved-gas analysis; winding and insulation testing.
Preventive maintenance
Cleaning bushings, insulation and fins; tightening connections; replacing gaskets, sealants and consumables.
Oil care
Filtration to remove moisture and impurities, or replacement of degraded oil.
Load management
Balancing and optimising load to prevent overheating and overloading.
Protective maintenance
Alarm checks and calibration of relays, circuit breakers and protective devices.
Documentation and emergency support
Inspection reports, upgrade recommendations, and prompt repair or replacement of tap changers, bushings and fuses.
AMC scope
What each visit covers
Quarterly visit
- Inspection of oil level and oil leakages
- Breather condition
- Inspection of HV and LV insulators for cracks and dirt
- Metal parts checking
- Inspection of OTI, WTI, PRV, Buchholz relay, OSR and explosion vent
- Radiator ventilation for proper cooling
- OLTC functions (if available)
- Insulation resistance check
- Inspection and testing of tripping and earthing systems
- Oil breakdown voltage (BDV)
- Reporting of any abnormality during operation
Annual visit
- All quarterly-visit services
- Main cover or inspection window removal, and sludge removal by oil jet
- Inspection of tap changer, conservator and oil-level indicator
- Oil filtration to improve BDV, IR values and acidity
- Replacement of HV and LV rubber or cork gaskets and oil seals
- Tightening or refitting of HV and LV terminals and cables
- Magnetic balance, ratio test on all taps, winding resistance and polarisation index (if required)
- Outer surface cleaning and de-rusting
We are developing IoT-enabled condition monitoring to support preventive maintenance.
What we maintain
Power and distribution transformers up to 132 kV
We supply utilities with high-efficiency transformers and related components for systems up to 132 kV, with robust insulation systems, low-loss core designs and precision windings.
Single-phase auxiliary transformers
For railways and auxiliary supplies: 11 kV input, 230 V or 433 V output, 5 kVA – 100 kVA.
Three-phase transformers
For commercial and industrial sites, 25 kVA – 3,150 kVA, up to 33 kV.
Data centre transformers
Low-loss units for continuous IT, UPS and cooling loads, up to 3,150 kVA and 33 kV.
Pad-mounted transformers
For urban and utility distribution networks: tamper-proof, outdoor type, with sealed tanks and dead-front construction.
Package substation (PSS) transformers with RMU and LVDB
Integrated system designed for quick installation and reliable fault management.
Power transformers
Step-up and step-down transformers with voltage regulation, 3.15 MVA – 50 MVA, up to 132 kV.
Dual-ratio transformers
Operate at two different voltage ratios, allowing flexibility in distribution.
Autotransformers
Common-winding design reduces material use and losses where a small voltage variation is required.
Rectifier transformers
For high currents and harmonic loads.
Solar inverter duty transformers
Step up solar inverter voltage to grid voltage: 100 kVA – 25 MVA, up to 66 kV.
Design features
- Copper or aluminium winding conductors: copper for conductivity, aluminium where economy matters
- CRGO steel cores that reduce no-load losses
- ONAN and ONAF cooling for temperature control in operation
- Oil and dry-type configurations
- High dielectric strength insulation systems
- Off-load or on-load tap changer options to match output voltage to supply conditions
Industries we serve
Set up an AMC
Tell us how many transformers, their ratings and locations, and we'll propose a maintenance plan.